![](/rp/kFAqShRrnkQMbH6NYLBYoJ3lq9s.png)
This section covers the welding of Petroleum, Oil and Lubricant (POL) Service systems. Deviations from applicable codes, approved procedures, and approved detail drawings will not be permitted without prior written approval by the Contracting Officer. Materials or …
Design Petroleum, Oil, and Lubricants Mandatory Center of Expertise must be followed.. PART 2 PRODUCTS 2.1 GOVERNMENT-FURNISHED MATERIAL AND EQUIPMENT The Government will furnish the following materials, equipment and services during the performance of the work under this section. 2.1.1 Aircraft Turbine Fuel
- [PDF]
USACE / NAVFAC
be used for gas station or petroleum/oil/lubricants (POL) facility canopies. Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide …
which receive, store, distribute, or dispense liquid petroleum fuels. It is also applicable to liquefied petroleum gases (LPG) and compressed natural gas (CNG) facilities. These criteria are applicable to all branches of the Department of Defense (DoD) and the Defense Logistics Agency (DLA).
ufc 3-201-01 1 june 2013 change 1, 1 march 2017 . unified facilities criteria (ufc) approved for public release; distribution unlimited . civil engineering
storage, transfer and issue of petroleum fuel products for non-hydrant SECTION 33 08 55 Page 5. fuel facility systems. It covers requirements for safety, Government scheduling and coordination, device testing, existing and new system cleanliness, system [flushing][flushing and cleaning], demonstration of
Hard copies of UFC printed from electronic media should be checked against the current electronic version prior to use to ensure that they are current. /1/
correct conditions, such as oil spills or debris, that occur during the dredging operations, must be provided. Comply with Federal, State, and local regulations pertaining to water, air, and noise pollution. 1.7 BASIS FOR BIDS ***** NOTE: USACE will reference Division 00 and Division 01 to ensure there is no redundancy or discrepancy. ...
- [PDF]
stg.wbdg.org
Report Date: 27-JUN-2019 08:33:51 11110 11112 11115 11120 11125 11130 11210 11320 CATEGORY CODE UNITS OF MEASURE AREA OTHER ALT TITLE LS LS LS LS LS LS LS LS [SY] [SY] [SY] [SY] [
c.Confirm correct application of manufacturer's recommended lubricants. d.Verify appropriate anchorage, required area clearances, and correct alignment. e.Verify that circuit breaker sizes and types correspond to approved shop drawings.